Manufacturer
FIGARO
|
- | Sensor | MOS | Methane (CH4) | 300...10 000ppm | - | ΔR | 0,52-0,65 | - | - | - mA | -40...+70°C | D22,4x9,2mm | Solid legs | - | - | - | - |
Manufacturer
FIGARO
|
- | Sensor | Electrochemical | Carbon monoxide (CO) | 0...10 000ppm | - | Current | - | - | - | - mA | 0...+50°C | D49x20,9mm | - | Battery operable electrochemical sensor | - | - | - |
Manufacturer
FIGARO
|
- | Sensor | Electrochemical | Carbon monoxide (CO) | 0...5 000ppm | - | Current | - | - | - | - mA | -10...+50°C | D10,8x13,9mm | Solid legs | Battery operable electrochemical sensor | - | - | - |
Manufacturer
FIGARO
|
- | Sensor | MOS | Air contaminants | 1...100ppm | - | ΔR | - | - | - | - mA | -10...+50°C | 3,2x2,5x0,99mm | SMD | - | - | - | - |
Manufacturer
FIGARO
|
- | Sensor | MOS | Combustible gases (Methane, Propane, Iso-butane) | 500...10 000ppm | - | ΔR | - | - | - | - mA | -40...+70°C | D16,5x17mm | Solid legs | - | - | - | - |
Manufacturer
FIGARO
|
- | Sensor | MOS | Organic solvent vapors, ethanol | 50...5 000ppm | - | ΔR | - | - | - | - mA | -10...+40°C | D16,5x17mm | Solid legs | - | - | - | - |
Manufacturer
SGX SENSORTECH
|
- | Module | Thermal Conductivity (H2), MOS (CO, NH3) | - | - | - | LIN 2.1 | - | ± 0,4% @ (Temp 0...25°C, RH 10...95%) | 9...15V | 80mA (max) @ 12V mA | -40...+85°C | 39x35x27mm | Connector | IP6K7, pressure measurement 20...250 kPa over the air pressure | - | - | - |
Manufacturer
SGX SENSORTECH
|
VQ500 | Sensor | Thermal Conductivity | Mixture of known gas and air | x…100% *1 | - | ΔR | 4mV/% CH4, Min. | - | 4,25V | 50...60mA mA | -40...+55°C | D20x16,5mm | Pins for socket | ATEX: II 2G Ex db IIC Gb, I M2 Ex db I Mb, IECEx: Ex db IIC | MSL 1 | Voltage | *1: x depends on gas |
Manufacturer
SGX SENSORTECH
|
VQ500 | Sensor | Catalytic | Ammonia (NH3) | 0...15% | - | ΔR | 21 mV/% NH3, Min. | - | 3V | 40...50mA mA | -40...+55°C | D20x16,5mm | Pins for socket | ATEX: II 2G Ex db IIC Gb, I M2 Ex db I Mb, IECEx: Ex db IIC | MSL 1 | Voltage | - |
Manufacturer
SGX SENSORTECH
|
VQ500 | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | 8mV/% CH4, Min | - | 3V | 37...41mA mA | -20...+60°C | D20x16,5mm | Pins for socket | ATEX: II 1G Ex da IIC Ga, I M1 Ex da I Ma, IECEx: Ex da IIC | - | Voltage | - |
Manufacturer
SGX SENSORTECH
|
VQ500 | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | 20 mV/% CH4, Min. | - | 3V | 67...80mA mA | -40...+55°C | D20x16,5mm | Pins for socket | ATEX: II 2G Ex db IIC Gb, I M2 Ex db I Mb, IECEx: Ex db IIC | MSL 1 | Voltage | Poison resistant |
Manufacturer
SGX SENSORTECH
|
VQ500 | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | 30 mV/% CH4, Min. | - | 4,25V | 50...60mA mA | -40...+55°C | D20x16,5mm | Pins for socket | ATEX: II 2G Ex db IIC Gb, I M2 Ex db I Mb, IECEx: Ex db IIC | MSL 1 | Voltage | Poison and shock resistant |
Manufacturer
SGX SENSORTECH
|
- | Accessory | - | - | - | - | - | - | - | - | - mA | - | - | - | - | MSL 1 | - | - |
Manufacturer
NISSHA FIS
|
- | Sensor | MOS | Hydrogen (H2) | 300...10 000ppm | - | ΔR | - | - | - | - mA | -10...+50°C | D9,6x15mm | Pins for socket | - | - | - | - |
Manufacturer
NISSHA FIS
|
- | Sensor | MOS | Hydrogen sulfide (H2S) | 3...1 000ppm | - | ΔR | - | - | - | - mA | -10...+50°C | D13,4x7,6mm | Pins for socket | - | - | - | - |
Manufacturer
SGX SENSORTECH
|
- | Accessory | - | - | - | - | - | - | - | - | - mA | - | - | - | - | - | - | - |
Manufacturer
SGX SENSORTECH
|
- | Accessory | - | - | - | - | - | - | - | - | - mA | - | - | - | - | MSL 1 | - | - |
Manufacturer
SGX SENSORTECH
|
4 series | Sensor | Electrochemical | Chlorine dioxide (ClO2) | 0...1ppm | - | Current | 650 ± 300 nA/ppm | - | - | - mA | -20...+50°C | D20x16,6mm | Pins for socket | - | - | - | - |
Manufacturer
SGX SENSORTECH
|
4 series | Sensor | Electrochemical | Ethylene oxide (C2H4O) | 0...10ppm | - | Current | 1900 ± 800 nA/ppm | - | - | - mA | -20...+50°C | D20x16,6mm | Pins for socket | - | - | - | - |
Manufacturer
SGX SENSORTECH
|
4 series | Sensor | Electrochemical | Hydrogen sulfide (H2S) | 0...1000ppm | - | Current | 90 ± 40 nA/ppm | - | - | - mA | -20...+50°C | D20x16,6mm | Pins for socket | - | - | - | - |
Manufacturer
SGX SENSORTECH
|
4 series | Sensor | Electrochemical | Phosphine (PH3) | 0...20ppm | - | Current | - | - | - | - mA | - | D20x16,6mm | Pins for socket | - | - | - | - |
Manufacturer
SGX SENSORTECH
|
4 series | Sensor | Electrochemical | Nitrogen monoxide (NO) | 0...2000ppm | - | Current | 42,5 ± 21,5 nA/ppm | - | - | - mA | -20...+50°C | D20x16,6mm | Pins for socket | - | - | - | - |
Manufacturer
SGX SENSORTECH
|
4 series | Sensor | Electrochemical | Sulfur dioxide (SO2) | 0...2000ppm | - | Current | 20 ± 8 nA/ppm | - | - | - mA | -20...+50°C | D20x16,6mm | Pins for socket | - | - | - | - |
Manufacturer
SGX SENSORTECH
|
4 series | Sensor | Electrochemical | Chlorine dioxide (ClO2) | 0...50ppm | - | Current | 400 ± 180 nA/ppm | - | - | - mA | -20...+50°C | D20x16,6mm | Pins for socket | - | - | - | - |
Manufacturer
SGX SENSORTECH
|
INIR | Sensor | NDIR | Butane (C4H10) | 0...1,8% | - | UART, Voltage 1,25…2,5V | - | ±6% or 0,06% FS, *1 | 3,2...5,25V | 32mA [ 3,3V, Typ. mA | -40...+75°C | D20x16,6mm | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb | - | - | *1: Whichever error is larger |