Overvoltages in mains line are a quite frequent matter. Who doesn´t have a lightning conductor usually knows, that he undergoes some risk. However, vast majority of new buildings is equipped with a lightning conductor and its own earthing, what can make a feeling, that “we´re protected”. Of course, a quality lightning conductor and earthing are basic prerequisites of a reliable electro-installation, but it´s only the first step. The problem is that:

1) overvoltage (surge) can arrive anytime (and it comes) by a mains line from outside. Sources of surges in mains line are (distant) flashes and also various motors, switched inductive loads and other.

2) a discharge at lightning hit is able to induce voltage even to distant conductors and also to significantly increase voltage on a PE(+N) conductor. Current in orders of kA flowing to earth creates up to kV voltages (R*I) even on high quality earthing. This voltages will get through an equipotential point in a distribution box to practically all PE+N conductors (in the most common TN-C-S network). In praxis it means, that if you don´t have a suitable surge protection installed (SPD), then all mains sockets connected to given distribution box will be exposed to this high voltage. A portion of a discharge usually flows also through incoming PE conductor (from a building to a mains line) and also through all equipotentially conducted media (water, gas, heating, air conditioning, …). This also contributes spreading a high voltage into various places in a building.

That´s why various components for elimination of surges (SPDs) are available on the market. Majority of flashes and following surges is usually quite short - units to tens of microseconds, that´s why even surges in a mains line are “manageable”. The most common goal of every SPD component is to equalize potential (against earth or at least among given conductors). At a direct lightning hit, it´s us usually impossible to avoid status when for example all the installation has 1000V to earth, but it doesn´t have to be fatal for our devices - it´s only essential, that all conductors had more-less the same potential in a given moment..

Are your devices protected from lightning and overvoltages?
Usually we classify 3 basic SPD levels:

Type 1 - „rough“ protection. Usually installed outside a building or into the first distribution box inside a building. It is usually based on usage of a surge arrester (gas filled) spark gap. This SPD is able to eliminate high energy amount thanks to a small voltage on a component during its action. However only this protection is not enough, because a spark gap is slow and at high dV/dT it starts to act at quite high voltage. Advantageous is its small capacity and very low leakage current.

Type 2 - is the most common protection used in distribution boxes, Usually it´s based on a varistor (with a thermal fuse). This protection is faster and represents sufficient solution for majority of cases (ideally in combination type 1 + type 2). Disadvantage is that a varistor has certain capacity, that´s why it can cause problems if installed behind a residual current circuit breaker (RCCB) - because of a leakage current (L-PE). For these cases, combined SPDs with varistor and spark gap in series are available.

Type 3 - fine protection. Usually based on a varistor, or also in combination with a transil (suppressor diode). This protection is required for sensitive devices with microprocessors, computers and other “fine” equipment. It has the biggest effect if installed near a protected device or directly in a given socket.

Are your devices protected from lightning and overvoltages?
In praxis it´s good to reach some length of a cable among particular SPD stages, which acts as an inductor thus limiting a speed of voltage rising. . If it isn´t possible, then external inductors are used, often integrated into combined SPD components (for example type 1+ type 2 in one unit).

Company Phoenix-Contact offers comprehensive and sophisticated system of SPD components under name Trabtech. In a Surge protection user guide can be found a short overview of most often used components and examples of usage. An important fact at Phoenix-Contact SPD components (Flashtrab, Valvetrab,...) is, that they have exchangeable elements, i.e. in case of damage, only a varistor portion itself can be exchanged. Choice of a suitable component is important, even in respect to a type of a network which you have in a building. Very important is also its placing in a distribution box, so that (L-PE) conductors were as short as possible and sufficiently thick and not to create a loop around other conductors.
Closer about this problematic can be found in the document Phoenix Contact Fundamentals for Surge Protection.
In case of interest in any SPD component from Phoenix Contact, please contact us at sales@soselectronic.com.

Advantages / Features: :
  • SPD components suitable for all applications
  • available for protection of data and coaxial lines
  • comprehensive system with wide variability
  • exchangeable active parts
Do not miss these articles

Do you like our articles? Do not miss any of them! You do not have to worry about anything, we will arrange delivery to you.

Additional products


FLT-CP-PLUS-3S-350 (2882640) PHOENIX CONTACT  
FLT-CP-PLUS-3S-350 (2882640)

Surge Protection Device L1, L2, L3, PE, N 350VAC 125A, DIN-rail

Overvoltage Protection

Ord. No.: 166805
Manufacturer: PHOENIX CONTACT
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare
Get Quote

PT 4-PE/S-230AC/FM (2882459) PHOENIX CONTACT  
PT 4-PE/S-230AC/FM (2882459)

Surge Protection Device Type 3, L1, L2, L3, N, PE, 230V 26A, DIN-rail

Overvoltage Protection

Ord. No.: 166858
Manufacturer: PHOENIX CONTACT
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare
Get Quote

SFP 1-20/230AC (2859987) PHOENIX CONTACT  
SFP 1-20/230AC (2859987)

Surge Protection Device Type 3 + Filter, L1, N, PE, 230V 20A, DIN-rail

Overvoltage Protection

Ord. No.: 166856
Manufacturer: PHOENIX CONTACT
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare
Get Quote

VAL-MS-T1/T2 335/12.5/1+0 (2801041) PHOENIX CONTACT  
VAL-MS-T1/T2 335/12.5/1+0 (2801041)

Surge Protection Device Type 1/2, N, PE, 335VAC 80A, DIN-rail

Overvoltage Protection

Ord. No.: 166175
Manufacturer: PHOENIX CONTACT
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare
Get Quote

VAL-MS-T1/T2 335/12.5/3+0 (2800189) PHOENIX CONTACT  
VAL-MS-T1/T2 335/12.5/3+0 (2800189)

Surge Protection Device Type 1/2, L1, L2, L3, PEN, 335VAC 80A, DIN-rail

Overvoltage Protection

Ord. No.: 166176
Manufacturer: PHOENIX CONTACT
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare
Get Quote

VAL-MS-T1/T2 335/12.5/3+1 (2800184) PHOENIX CONTACT  
VAL-MS-T1/T2 335/12.5/3+1 (2800184)

Surge Protection Device Type 1/2, L1, L2, L3, N, PE, 335VAC 80A, DIN-rail

Overvoltage Protection

Ord. No.: 166180
Manufacturer: PHOENIX CONTACT
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare
Get Quote

VAL-MS-T1/T2 335/12.5/4+0 (2800645) PHOENIX CONTACT  
VAL-MS-T1/T2 335/12.5/4+0 (2800645)

Surge Protection Device Type 1/2, L1, L2, L3, N, PE, 335VAC 80A, DIN-rail

Overvoltage Protection

Ord. No.: 166182
Manufacturer: PHOENIX CONTACT
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare
Get Quote

VAL-MS 230/1+1 (2804429) PHOENIX CONTACT  
VAL-MS 230/1+1 (2804429)

Surge Protection Device Type 2, L1, N, PEN, 275VAC 80A, DIN-rail

Overvoltage Protection

Ord. No.: 166802
Manufacturer: PHOENIX CONTACT
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare
Get Quote

VAL-MS 230/3+1 PHOENIX CONTACT  
VAL-MS 230/3+1

Surge Protection Device Type 2, L1, L2, L3, N, PE, 275VAC 80A, DIN-rail

Overvoltage Protection

Ord. No.: 166797
Manufacturer: PHOENIX CONTACT
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare
Get Quote

VAL-MS 320/3+0 (2920230) PHOENIX CONTACT  
VAL-MS 320/3+0 (2920230)

Surge Protection Device Type 2, L1, L2, L3, N, PE, 335VAC 80A, DIN-rail

Overvoltage Protection

Ord. No.: 166803
Manufacturer: PHOENIX CONTACT
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare
Get Quote

VAL-MS 385/65/3+1 (2920890) PHOENIX CONTACT  
VAL-MS 385/65/3+1 (2920890)

Surge Protection Device Type 2, L1, L2, L3, N, PE, 385VAC 80A, DIN-rail

Overvoltage Protection

Ord. No.: 166801
Manufacturer: PHOENIX CONTACT
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare
Get Quote
Do you agree with cookies being stored?
Welcome to the SOS electronic website. Before you enter our online world, we would like to ask you to allow us to store cookies on your browser. Your consent will help us view the site without error, measure its performance, and track additional statistics. Apart from that, we can bring you an offer of our products and services, literally tailor-made. We also provide cookies to third parties. However, you are definitely safe with us.
The proper operation of the website
More stable technical control
Better marketing offer
Necessary Only selected Accept all cookies
Change the settings
Country
Select the country you are located in to receive relevant information and services tailored to your region.
Choose a language
Select your preferred language for displaying website content and communicating with our support.
Currency
Select the currency in which you want to see product prices. This way, we ensure you see current prices tailored to your needs.
Show prices with VAT
Select whether you want to display prices with or without VAT to have a better overview of costs.
Prices without VAT Prices incl. VAT