Manufacturer
SGX SENSORTECH
|
- | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | 10 mV/% CH4, Min. | - | 2V | 175mA, Typ. mA | - | D11x8,4mm | Solid legs | - | MSL 1 | Voltage | Poison resistant |
Manufacturer
SGX SENSORTECH
|
- | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | 15 mV/% CH4, Min. | - | 2,5V | 335mA, Typ. mA | - | D11,3x8,9mm | Solid legs | - | MSL 1 | Voltage | Poison resistant |
Manufacturer
SGX SENSORTECH
|
- | Sensor | Catalytic | Combustible gases | - | - | ΔR | 25 mV/% n-butane, Min. | - | 2V | 335mA, Typ. mA | - | D11x8,4mm | Solid legs | - | - | Voltage | Poison resistant |
Manufacturer
SGX SENSORTECH
|
- | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | 15 mV/% CH4, Min. | - | 2V | 175mA, Typ. mA | - | D11x8,4mm | Solid legs | - | - | Voltage | - |
Manufacturer
SGX SENSORTECH
|
- | Sensor | Thermal Conductivity | Mixture of known gas and air | x…100% *1 | - | ΔR | 2,5 mV/% CH4, Typ, [3,5V | - | 2...3,5V | 90mA ,Typ. [ 3,5V mA | - | D11x8,8mm | Solid legs | - | MSL 1 | Voltage | *1: x depends on gas |
Manufacturer
SGX SENSORTECH
|
- | Sensor | Catalytic | Combustible gases | 0...10% CH4 | - | ΔR | 21 mV/% CH4, Min. | - | 2,5V | 335mA, Typ. mA | - | D11x6,9mm | Solid legs | - | - | Voltage | - |
Manufacturer
SGX SENSORTECH
|
- | Sensor | Catalytic | Ammonia (NH3) (Hydrogen (H2)) | 0...1,5% | - | ΔR | 15 mV/% NH3, Min., 45 mV/% H2 Typ. | - | 2V | 100mA, Typ. mA | - | D11,3x8,9mm | Solid legs | - | - | Voltage | - |
Manufacturer
SGX SENSORTECH
|
VQ500 | Sensor | Thermal Conductivity | Mixture of known gas and air | x…100% *1 | - | ΔR | -4mV/% CH4, Min. | - | 4,25V | 50...60mA mA | -40...+55°C | D20x16,5mm | Pins for socket | ATEX: II 2G Ex db IIC Gb, I M2 Ex db I Mb, IECEx: Ex db IIC | MSL 1 | - | *1: x depends on gas |
Manufacturer
SGX SENSORTECH
|
VQ500 | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | 20 mV/% CH4, Min. | - | 3V | 67...80mA mA | -40...+55°C | D20x16,5mm | Pins for socket | ATEX: II 2G Ex db IIC Gb, I M2 Ex db I Mb, IECEx: Ex db IIC | - | Voltage | Poison resistant |
Manufacturer
SGX SENSORTECH
|
VQ500 | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | 20 mV/% CH4, Min. | - | 3V | 67...80mA mA | -40...+55°C | D20x16,5mm | Pins for socket | ATEX: II 2G Ex db IIC Gb, I M2 Ex db I Mb, IECEx: Ex db IIC | - | Voltage | Poison and shock resistant |
Manufacturer
SGX SENSORTECH
|
VQ500 | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | 30 mV/% CH4, Min. | - | 4,25V | 50...60mA mA | -40...+55°C | D20x16,5mm | Pins for socket | ATEX: II 2G Ex db IIC Gb, I M2 Ex db I Mb, IECEx: Ex db IIC | - | Voltage | Poison and shock resistant |
Manufacturer
SGX SENSORTECH
|
- | Sensor | Thermal Conductivity | Mixture of known gas and air | x…100% *1 | - | ΔR | 1 mV/% CH4, Typ | - | 2V | 175mA, Typ. mA | - | D11x8,8mm | Solid legs | - | - | Voltage | *1: x depends on gas |
Manufacturer
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Combustible gases | 0...10% CH4 | - | ΔR | 20 mV/% CH4, Min. | - | 2V | 300mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | - |
Manufacturer
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Combustible gases | 0...10% CH4 | - | ΔR | 20 mV/% CH4, Min. | - | 2V | 300mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | - |
Manufacturer
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Combustible gases | 0...10% CH4 | - | ΔR | 20 mV/% CH4, Min. | - | 2V | 300mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | - |
Manufacturer
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Combustible gases | 0...10% CH4 | - | ΔR | 21 mV/% CH4, Min. | - | 2,5V | 335mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | - |
Manufacturer
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Combustible gases | 0...10% CH4 | - | ΔR | 21 mV/% CH4, Min. | - | 2,5V | 335mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | - |
Manufacturer
SGX SENSORTECH
|
VQ600 | Sensor | Thermal Conductivity | Mixture of known gas and air | x…100% *1 | - | ΔR | 1 mV/% CH4, Typ | - | 2V | 175mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | *1: x depends on gas |
Manufacturer
SGX SENSORTECH
|
VQ600 | Sensor | Thermal Conductivity | Mixture of known gas and air | x…100% *1 | - | ΔR | 1 mV/% CH4, Typ | - | 2V | 300mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | *1: x depends on gas |
Manufacturer
SGX SENSORTECH
|
VQ600 | Sensor | Thermal Conductivity | Mixture of known gas and air | x…100% *1 | - | ΔR | 1 mV/% CH4, Typ | - | 2V | 300mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | *1: x depends on gas |
Manufacturer
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | 15 mV/% CH4, Min. | - | 2V | 300mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | - |
Manufacturer
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | 15 mV/% CH4, Min. | - | 2V | 300mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | - |
Manufacturer
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | 15 mV/% CH4, Min. | - | 2V | 300mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | - |
Manufacturer
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | - | - | 2V | 300mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | - | Voltage | - |
Manufacturer
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | - | - | 2V | 300mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | - |