Manufacturer
SGX SENSORTECH
|
7 series | Sensor | Electrochemical | Hydrogen sulfide (H2S) | 0...200ppm | - | Current | 370 ± 100 nA/ppm | - | - | - mA | -30...+50°C | D31,5x15,5mm | Pins for socket | - | - | Current | - |
Manufacturer
SGX SENSORTECH
|
7 series | Sensor | Electrochemical | Ammonia (NH3) | 0...100ppm | - | Current | 115 ± 45 nA/ppm | - | - | - mA | -40...+50°C | D31,5x15,5mm | Pins for socket | - | - | Current | - |
Manufacturer
SGX SENSORTECH
|
7 series | Sensor | Electrochemical | Ammonia (NH3) | 0...1000ppm | - | Current | 8 ± 4 nA/ppm | - | - | - mA | -40...+50°C | D31,5x15,5mm | Pins for socket | - | - | Current | - |
Manufacturer
SGX SENSORTECH
|
7 series | Sensor | Electrochemical | Nitrogen monoxide (NO) | 0...100ppm | - | Current | 550 ± 150 nA/ppm | - | - | - mA | -30...+50°C | D31,5x15,5mm | Pins for socket | - | - | Current | - |
Manufacturer
SGX SENSORTECH
|
7 series | Sensor | Electrochemical | Nitrogen dioxide (NO2) | 0...20ppm | - | Current | 1400 ± 300 nA/ppm | - | - | - mA | -30...+50°C | D31,5x15,5mm | Pins for socket | - | - | Current | - |
Manufacturer
SGX SENSORTECH
|
7 series | Sensor | Electrochemical | Oxygen (O2) | 0...25% | - | Current | - | - | - | - mA | -30...+50°C | D31,5x15,5mm | Pins for socket | - | - | Current | - |
Manufacturer
SGX SENSORTECH
|
7 series | Sensor | Electrochemical | Sulfur dioxide (SO2) | 0...100ppm | - | Current | 370 ± 70 nA/ppm | - | - | - mA | -30...+50°C | D31,5x15,5mm | Pins for socket | - | - | Current | - |
Manufacturer
SGX SENSORTECH
|
- | Module | MOS | Carbon monoxide (CO), Nitrogen dioxide (NO2), Ammonia (NH3) | - | - | LIN 2.1, Air quality level 0...100% | - | - | 8...18V | 45 mA max. @ 13,5V mA | n/a | 39x35x27mm | Connector, AMP 967642-1 Coding B | IP6K6K | - | - | Uses MiCS-6814 |
Manufacturer
SGX SENSORTECH
|
- | Sensor | Electrochemical | Oxygen (O2) | 0...100% | - | Voltage | - | - | - | - mA | -20...+50°C | D29,3x38,2mm | Connector | - | - | Current | - |
Manufacturer
SGX SENSORTECH
|
- | Sensor | Thermal Conductivity | Mixture of known gas and air | x…100% *1 | - | ΔR | 1 mV/% CH4, Typ | - | 4,25V | 55mA, Typ. mA | - | D11x8,8mm | Solid legs | - | MSL 1 | Voltage | *1: x depends on gas |
Manufacturer
SGX SENSORTECH
|
VQ500 | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | 12mV/% CH4, Min | - | 3V | 39...42mA mA | -20...+60°C | D20x16,5mm | Pins for socket | ATEX: II 1G Ex ia IIC Ga, I M1 Ex ia I Ma, IECEx: Ex ia IIC | - | Voltage | - |
Manufacturer
SGX SENSORTECH
|
VQ500 | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | 12mV/% CH4, Min | - | 3V | 39...42mA mA | -20...+60°C | D20x16,5mm | Pins for socket | ATEX: II 1G Ex da IIC Ga, I M1 Ex da I Ma, IECEx: Ex da IIC | MSL 1 | Voltage | - |
Manufacturer
SGX SENSORTECH
|
- | Accessory | - | - | - | - | - | - | - | - | - mA | - | - | - | - | - | - | - |
Manufacturer
SGX SENSORTECH
|
INIR2 | Sensor | NDIR | Butane (C4H10) | 0...1,8% | - | - | - | - | - | - mA | - | - | - | - | - | - | - |
Manufacturer
SGX SENSORTECH
|
INIR4 | Sensor | NDIR | Refrigerants (R290) | 0...2,1% | 0,42% (20% LEL), SW configurable | UART, PWM (100Hz, duty cycle 10...90%) | Resolution ± 0,005% FS | ±10% or 0,1% FS, *1 | 3,2...5,25 V | 32 mA (Typ) @ 5 V mA | -20...+60°C | 39,7 x 19,8 x 10,7 mm | Pins for socket | Meets UL 60335-2-40 / IEC 60079-29-1 / IEC60335-2-40 | - | TTL Levels | *1: Whichever error is larger , Do not solder sensor pins |
Manufacturer
SGX SENSORTECH
|
INIR4 | Sensor | NDIR | Refrigerants (R32) | 0...7% | 2,8% (20% LEL) | UART, PWM (100Hz, duty cycle 10...90%) | Resolution ± 0,005% FS | ±10% or 0,1% FS, *1 | 3,2...5,25 V | 32 mA (Typ) @ 5 V mA | -20...+60°C | 39,7 x 19,8 x 10,7 mm | Pins for socket | Atex: II 1G Ex ia IIB T4 Ga, IECEx: Ex ia IIB T4 Ga, dual channel | - | TTL Levels | *1: Whichever error is larger , Do not solder sensor pins |
Manufacturer
SGX SENSORTECH
|
IR1 | Sensor | NDIR | Carbon dioxide (CO2) | 0…5% | - | ΔV | - | - | 3...5V | 96mA [ 5V, Typ. mA | -20...+55°C | D20x19mm | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 | - | - |
Manufacturer
SGX SENSORTECH
|
IR1 | Sensor | NDIR | Carbon dioxide (CO2) | 0...100% | - | ΔV | - | - | 3...5V | 96mA [ 5V, Typ. mA | -20...+55°C | D20x19mm | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 | - | - |
Manufacturer
SGX SENSORTECH
|
IR1 | Sensor | NDIR | Carbon dioxide (CO2) | 0...5% | - | ΔV | - | - | 3...5V | 96mA [ 5V, Typ. mA | -20...+55°C | D20x19mm | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 | - | - |
Manufacturer
SGX SENSORTECH
|
IR1 | Sensor | NDIR | Carbon dioxide (CO2) | 0...5% | - | ΔV | - | - | 3...5V | 96mA [ 5V, Typ. mA | -20...+55°C | D20x16,9mm | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 | - | - |
Manufacturer
SGX SENSORTECH
|
IR1 | Sensor | NDIR | Carbon dioxide (CO2) | 0...5% | - | ΔV | - | - | 3...5V | 96mA [ 5V, Typ. mA | -20...+55°C | D20x19mm | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 | - | - |
Manufacturer
SGX SENSORTECH
|
IR1 | Sensor | NDIR | Carbon dioxide (CO2) | 0...5% | - | ΔV | - | - | 3...5V | 96mA [ 5V, Typ. mA | -20...+55°C | D20x16,9mm | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 | - | - |
Manufacturer
SGX SENSORTECH
|
IR1 | Sensor | NDIR | Hydrocarbons | 0...100% | - | ΔV | - | - | 3...5V | 96mA [ 5V, Typ. mA | -20...+55°C | D20x19mm | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 | - | - |
Manufacturer
SGX SENSORTECH
|
IR1 | Sensor | NDIR | Hydrocarbons | 0...100% | - | ΔV | - | - | 3...5V | 96mA [ 5V, Typ. mA | -20...+55°C | D20x19mm | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 | - | - |
Manufacturer
SGX SENSORTECH
|
IR1 | Sensor | NDIR | Hydrocarbons | 0...100% | - | ΔV | - | - | 3...5V | 96mA [ 5V, Typ. mA | -20...+55°C | D20x16,9mm | Pins for socket | ATEX: II 2G Ex db IIC Gb, IECEx: Ex db IIC Gb, dual channel | MSL 1 | - | - |