NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO), Propane | - | CO: 300ppm, Propane: 2 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 31 x 44 x 20 mm | Connector | SB-96-00 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO), Propane | - | CO: 300ppm, Propane: 2 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 28 x 41 x 20 mm | Connector | SB-96-00 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Methane (CH4) | - | 3 000ppm, 5 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 31 x 44 x 20 mm | Connector | SB-12A-00 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Hydrogen (H2) | - | 3 000ppm, 6 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 31 x 44 x 20 mm | Connector | SB-42A-11 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Hydrogen (H2) | - | 3 000ppm, 6 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 28 x 41 x 20 mm | Connector | SB-42A-11 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO) | - | 300ppm | - | - | - | 5V | - mA | -10...+50°C | 31 x 44 x 20 mm | Connector | SB-500-12 Sensor, With case, Malfunction output | - | Open collector | - |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO) | - | 300ppm | - | - | - | 5V | - mA | -10...+50°C | 28 x 41 x 20 mm | Connector | SB-500-12 Sensor, Malfunction output | - | CMOS 5V | - |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO) | - | 100ppm, 300ppm | UART | - | - | 5V | - mA | -10...+50°C | 31 x 44 x 20 mm | Connector | SB-500-12 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO) | - | 100ppm, 300ppm | UART | - | - | 5V | - mA | -10...+50°C | 28 x 41 x 20 mm | Connector | SB-500-12 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Propane | - | 1 000ppm, 2 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 31 x 44 x 20 mm | Connector | SB-15B-00 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Propane | - | 1 000ppm, 2 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 28 x 41 x 20 mm | Connector | SB-15B-00 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Alcohol, Hydrogen (H2), Organic solvents | - | Ethanol: 300ppm, 1 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 31 x 44 x 20 mm | Connector | SB-AQ1-00 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Alcohol, Hydrogen (H2), Organic solvents | - | Ethanol: 300ppm, 1 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 28 x 41 x 20 mm | Connector | SB-AQ1-00 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Refrigerants (R-410A) | - | R-410A: 1 000ppm, 5 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 31 x 44 x 20 mm | Connector | SB-43 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Refrigerants (R-410A) | - | R-410A: 1 000ppm, 5 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 28 x 41 x 20 mm | Connector | SB-43 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Refrigerants (R22) | - | R-22: 1 000ppm, 2 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 31 x 44 x 20 mm | Connector | SB-43 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Refrigerants (R22) | - | R-22: 1 000ppm, 2 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 28 x 41 x 20 mm | Connector | SB-43 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Refrigerants (R32) | - | R-32: 1 000ppm, 5 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 31 x 44 x 20 mm | Connector | SB-43 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Refrigerants (R32) | - | R-32: 1 000ppm, 5 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 28 x 41 x 20 mm | Connector | SB-43 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Ammonia (NH3) | - | 100ppm, 300ppm | UART | - | - | 5V | - mA | -10...+50°C | 31 x 44 x 20 mm | Connector | SB-53 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Ammonia (NH3) | - | 100ppm, 300ppm | UART | - | - | 5V | - mA | -10...+50°C | 28 x 41 x 20 mm | Connector | SB-53 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Sulfides | - | H2S: 100ppm, 300ppm | UART | - | - | 5V | - mA | -10...+50°C | 31 x 44 x 20 mm | Connector | SB-51 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Sulfides | - | H2S: 100ppm, 300ppm | UART | - | - | 5V | - mA | -10...+50°C | 28 x 41 x 20 mm | Connector | SB-51 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Výrobca
NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO) | 10...100ppm | - | UART | - | - | 3,3V | 18 mA | -10...+50°C | 28 x 41 x 20 mm | Connector | SB-AQ9-00 Sensor | - | - | - |
Výrobca
NISSHA FIS
|
FIS5084 | Module | MOS | Refrigerants (R32) | - | R32: 6 000ppm | UART | - | - | 5V | 40 mA | -25...+60°C | 53 x 30 x 23,5 mm | Connector | SB-43A Sensor, Malfunction output, with case | - | PWM: 225ms H, 150ms L | Accuracy of gas concentration output is not guaranteed |