Notice

You are currently browsing the website for customers from Slovakia. We recommend switching to the United States version of the site, optimized for your region.
Slovakia
€ EUR
Prices without VAT

VOC Sensor with 65uA Consumption Only

SGPC3 is designed to measure the volatile organic compounds (VOC) concentration in the indoor environment. As is usual with Sensirion products, the sensor is calibrated and the signal processing is integrated directly on the chip.
This is an archive article published 07/03/2018. Some information may no longer be up to date and in line with the current state. Please contact us in case of interest.

SGPC3, as well as SGP30, is based on the SGP multi-pixel platform and MOXSens® siloxane-resistant technology. The table summarizes the main differences between SGPC3 and SGP30.

Why Measure VOC?

30% of new buildings have poor indoor air quality (IAQ), 20% of individuals complain about temporary or chronic pains due to poor IAQ (Sick Building Syndrome), increased VOC values have a significant negative effect on cognitive abilities like strategic thinking and decision making etc.

Current Consumption

After power-on or reset, the sensor goes into sleep mode with consumption 2uA.

Before the first measurement, it is necessary to warm-up the sensor for 16 to 184s depending on the sensor down-time. For details, see section 3.9 of the Driver Integration Guide Hardware Gas Sensors SGPC3. During this time, the sensor has a consumption of 48mA.

After sensor warm-up, it is possible to start the measurement. Measurement typically takes 40ms, consumption is 48mA. Once the measurement is completed, the sensor enters sleep mode. For proper function of the dynamic baseline compensation algorithm, the measurement must be run every 2 seconds.

If we neglect initial sensor warm-up and consumption during I2C bus communication, the average consumption will be: (40ms * 48mA + 1960ms * 0.002mA) / 2000ms = 0.98mA.

SGPC3 allows reducing the average consumption to 65uA. In this mode, you have to run the measurement every 30 seconds.

Dynamic Baseline Compensation

After the first power-on, the baseline is unknown. The sensor determines it as the minimum measured value of VOC concentration after twelve hours of operation. This value is valid for a maximum of one week. For more information, see the Driver Integration Guide Hardware Gas Sensors SGPC3.

The limitation of the validity period of the baseline results from the properties of the MOX (metal oxide semiconductor) sensor. The reference value corresponds to a certain resistance of the sensing elements. However, these resistances are not constant at a constant concentration of VOC. Within weeks or months, they will change to such an extent that it could affect measurement accuracy. The algorithm compensates these changes and continually corrects the baseline.

Temperature, Humidity and Airflow Influence

Ambient temperature and humidity changes causes the sensitivity characteristics offset in MOX sensors. SGPC3 has temperature-controlled micro-hotplate, which keeps temperature of the sensing element constant. To use built-in humidity compensation, just write actual absolute humidity value by Set_humidity command.

Airflow cools down MOX sensor sensing element and thereby changes its resistance. To prevent this, the top side of SGPC3 is covered by water and dust protection membrane, so the sensing element is not exposed to the airflow. In any case, it is always better to orient the sensor in such a way that the top side is parallel to the airflow.

If you are interested in any Sensirion product, or you need more information, we will be pleased to help. Please, contact us at sensirion@soselectronic.com

Features:
  • Outstanding long-term stability, siloxane-resistance
  • Current consumption only 65uA
  • Accuracy: typ. ±15% of meas. value in range 0.3 ppm to 30 ppm
  • Easy-to-integrate: I2C interface; 2.45 x 2.45 x 0.9mm DFN package; 1.8V power supply.

CONTENT: Get SGPC3 BOB-II for Free!

Competition with the following question has been published here:

What two data byte you have to write to SGPC3 for humidity compensation if absolute humidity is 12.25g/m3?

The correct answer was: 0x0C40

Thank you for all your responses.

Congratulations to winners. We´ll inform them by e-mail.

Do not miss these articles

Do you like our articles? Do not miss any of them! You do not have to worry about anything, we will arrange delivery to you.

Main products


SGP41 (SGP41-D-R4) SENSIRION  
SGP41 (SGP41-D-R4)

Volatile Organic Compounds (VOC) + NOx sensor

Gas Sensors

Ord. No.: 359695
Manufacturer: SENSIRION
in stock 276 pcs
1 pcs+
10 pcs+
50 pcs+
100 pcs+
500 pcs+
1000 pcs+
7,00 €
6,60 €
6,00 €
5,30 €
4,80 €
4,40 €
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare

Additional products


SGPC3 (SGPC3-2.5k) SENSIRION  
SGPC3 (SGPC3-2.5k)

Volatile Organic Compounds (VOC) sensor

Gas Sensors

Ord. No.: 289254
Manufacturer: SENSIRION
No longer available
Do you agree with cookies being stored?
Welcome to the SOS electronic website. Before you enter our online world, we would like to ask you to allow us to store cookies on your browser. Your consent will help us view the site without error, measure its performance, and track additional statistics. Apart from that, we can bring you an offer of our products and services, literally tailor-made. We also provide cookies to third parties. However, you are definitely safe with us.
The proper operation of the website
More stable technical control
Better marketing offer
Necessary Only selected Accept all cookies
Change the settings
Country
Select the country you are located in to receive relevant information and services tailored to your region.
Choose a language
Select your preferred language for displaying website content and communicating with our support.
Currency
Select the currency in which you want to see product prices. This way, we ensure you see current prices tailored to your needs.
Show prices with VAT
Select whether you want to display prices with or without VAT to have a better overview of costs.
Prices without VAT Prices incl. VAT