Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Refrigerants (R-410A) | - | R-410A: 5 000ppm | - | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-43 Sensor, With case, Malfunction output | - | Open collector | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Refrigerants (R-410A) | - | R-410A: 5 000ppm | - | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-43 Sensor, Malfunction output | - | CMOS 5V | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Refrigerants (R-410A) | - | R-410A: 1 000ppm, 5 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-43 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Refrigerants (R-410A) | - | R-410A: 1 000ppm, 5 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-43 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Refrigerants (R22) | - | R-22: 2 000ppm | - | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-43 Sensor, With case, Malfunction output | - | Open collector | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Refrigerants (R22) | - | R-22: 2 000ppm | - | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-43 Sensor, Malfunction output | - | CMOS 5V | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Refrigerants (R22) | - | R-22: 1 000ppm, 2 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-43 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Refrigerants (R22) | - | R-22: 1 000ppm, 2 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-43 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Refrigerants (R32) | - | R-32: 5 000ppm | - | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-43 Sensor, With case, Malfunction output | - | Open collector | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Refrigerants (R32) | - | R-32: 5 000ppm | - | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-43 Sensor, Malfunction output | - | CMOS 5V | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Refrigerants (R32) | - | R-32: 1 000ppm, 5 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-43 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Refrigerants (R32) | - | R-32: 1 000ppm, 5 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-43 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Ammonia (NH3) | - | 300ppm | - | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-53 Sensor, With case, Malfunction output | - | Open collector | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Ammonia (NH3) | - | 300ppm | - | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-53 Sensor, Malfunction output | - | CMOS 5V | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Ammonia (NH3) | - | 100ppm, 300ppm | UART | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-53 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Ammonia (NH3) | - | 100ppm, 300ppm | UART | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-53 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Sulfides | - | H2S: 300ppm | - | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-51 Sensor, With case, Malfunction output | - | Open collector | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Sulfides | - | H2S: 300ppm | - | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-51 Sensor, Malfunction output | - | CMOS 5V | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Sulfides | - | H2S: 100ppm, 300ppm | UART | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-51 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Sulfides | - | H2S: 100ppm, 300ppm | UART | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-51 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO) | 10...100ppm | - | UART | - | - | 3,3V | 18 mA | -10...+50°C | 28x41x20mm | Connector | SB-AQ9-00 Sensor | - | - | - |
Producent
NISSHA FIS
|
FIS5084 | Module | MOS | Refrigerants (R32) | - | R32: 6 000ppm | UART | - | - | 5V | 40 mA | -25...+60°C | 53x30x23,5mm | Connector | SB-43A Sensor, Malfunction output, with case | - | PWM: 225ms H, 150ms L | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
- | Accessory | - | - | - | - | - | - | - | - | - mA | - | - | - | - | - | - | For FIS5000 series |
Producent
SGX SENSORTECH
|
INIR2 | Sensor | NDIR | Butane (C4H10) | 0...1,8% | - | - | - | - | - | - mA | - | - | - | - | - | - | - |
Producent
SGX SENSORTECH
|
INIR4 | Sensor | NDIR | Refrigerants (R290) | 0...2,1% | 0,42% (20% LEL), SW configurable | UART, PWM (100Hz, duty cycle 10...90%) | Resolution ± 0,005% FS | ±10% or 0,1% FS, *1 | 3,2...5,25 V | 32 mA (Typ) @ 5 V mA | -20...+60°C | 39,7 x 19,8 x 10,7 mm | Pins for socket | Meets UL 60335-2-40 / IEC 60079-29-1 / IEC60335-2-40 | - | TTL Levels | *1: Whichever error is larger , Do not solder sensor pins |