Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO), Methane (CH4) | - | CO: 300ppm, CH4: 5 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-95-12 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO), Methane (CH4) | - | CO: 300ppm, CH4: 5 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-95-12 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO), Propane | - | CO: 300ppm, Propane: 2 000ppm | - | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-96-00 Sensor, With case, Malfunction output | - | Open collector x2 | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO), Propane | - | CO: 300ppm, Propane: 2 000ppm | - | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-96-00 Sensor, Malfunction output | - | CMOS 5V x2 | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO), Propane | - | CO: 300ppm, Propane: 2 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-96-00 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO), Propane | - | CO: 300ppm, Propane: 2 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-96-00 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Methane (CH4) | - | 5 000ppm | - | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-12A-00 Sensor, With case, Malfunction output | - | Open collector | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Methane (CH4) | - | 5 000ppm | - | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-12A-00 Sensor, Malfunction output | - | CMOS 5V | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Methane (CH4) | - | 3 000ppm, 5 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-12A-00 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Hydrogen (H2) | - | 6 000ppm | - | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-42A-11 Sensor, With case, Malfunction output | - | Open collector | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Hydrogen (H2) | - | 6 000ppm | - | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-42A-11 Sensor, Malfunction output | - | CMOS 5V | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Hydrogen (H2) | - | 3 000ppm, 6 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-42A-11 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Hydrogen (H2) | - | 3 000ppm, 6 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-42A-11 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO) | - | 300ppm | - | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-500-12 Sensor, With case, Malfunction output | - | Open collector | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO) | - | 300ppm | - | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-500-12 Sensor, Malfunction output | - | CMOS 5V | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO) | - | 100ppm, 300ppm | UART | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-500-12 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Carbon monoxide (CO) | - | 100ppm, 300ppm | UART | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-500-12 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Propane | - | 2 000ppm | - | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-15B-00 Sensor, With case, Malfunction output | - | Open collector | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Propane | - | 2 000ppm | - | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-15B-00 Sensor, Malfunction output | - | CMOS 5V | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Propane | - | 1 000ppm, 2 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-15B-00 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Propane | - | 1 000ppm, 2 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-15B-00 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Alcohol, Hydrogen (H2), Organic solvents | - | Ethanol: 1 000ppm | - | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-AQ1-00 Sensor, With case, Malfunction output | - | Open collector | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Alcohol, Hydrogen (H2), Organic solvents | - | Ethanol: 1 000ppm | - | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-AQ1-00 Sensor, Malfunction output | - | CMOS 5V | - |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Alcohol, Hydrogen (H2), Organic solvents | - | Ethanol: 300ppm, 1 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 31x44x20mm | Connector | SB-AQ1-00 Sensor, With case, Malfunction output | - | Open collector x2 | Accuracy of gas concentration output is not guaranteed |
Producent
NISSHA FIS
|
FIS3000 | Module | MOS | Alcohol, Hydrogen (H2), Organic solvents | - | Ethanol: 300ppm, 1 000ppm | UART | - | - | 5V | - mA | -10...+50°C | 28x41x20mm | Connector | SB-AQ1-00 Sensor, Malfunction output | - | CMOS 5V x2 | Accuracy of gas concentration output is not guaranteed |