Produttore
DIOTEC
|
- | Trench Field Stop | 650 V | 100 A | n/a | 2,1V @ 15V, 75A | n/a | n/a | 1,7mJ (on), 1,35mJ (off) | 28ns/152ns | Vcc=400V, Ic=75A, Rg=7,5 Ohm, Vge=15V | n/a | -40...+175°C (TJ) | Through Hole | TO-247-4 | - | - | - |
Produttore
DIOTEC
|
- | Trench Field Stop | 1 350 V | 60 A | n/a | 2,3V @ Vge=15V, Ic=30A | n/a | n/a | 3mJ (on), 1,5mJ (off) | 21ns/95ns | Vcc=600V, Ic=30A, Rg=4,7Ohm, Vge=15V, L=500uH | n/a | -55...+175°C (TJ) | Through Hole | TO-247-3 | - | - | - |
Produttore
DIOTEC
|
- | Trench Field Stop | 600 V | 60 A | n/a | 2,4V @ 15V, 30A | n/a | n/a | 1,2mJ (on), 0,5mJ (off) | 65ns/190ns | 400V, 30A, 10Ohm, 15V | n/a | -40...+150°C (TJ) | Through Hole | TO247 | - | - | - |
Produttore
DIOTEC
|
- | Trench Field Stop | 1 350 V | 80 A | n/a | 2,1V @ 15V, 40A | n/a | n/a | 3mJ (on), 1,5mJ (off) | 21ns/95ns | Vcc=600V, Ic=30A, Rg=4,7Ohm, Vge=15V, L=500uH | n/a | -55...+175°C (TJ) | Through Hole | TO-247-3 | - | - | - |
Produttore
DIOTEC
|
- | Trench Field Stop | 1 200 V | 80 A | n/a | 2,4V @ 15V, 40A | n/a | n/a | 3,2mJ (on), 2,3mJ (off) | 37ns/290ns | Vcc=600V, Ic=40A, Rg=4,7Ohm, Vge=15V, L=500uH | n/a | -40...+175°C (TJ) | Through Hole | TO-247-3 | - | - | - |
Produttore
DIOTEC
|
- | Trench Field Stop | 650 V | 100 A | n/a | 2,2V @ 15V, 50A | n/a | n/a | 3mJ (on), 1,1mJ (off) | 36ns/125ns | Vcc=400V, Ic=50A, Rg=10Ohm, Vge=15V, L=500uH | n/a | -55...+175°C | Through Hole | TO-247-3 | - | - | - |
Produttore
DIOTEC
|
- | Trench Field Stop | 650 V | 90 A | n/a | 1,9V @ 15V, 75A | n/a | n/a | 3,4mJ (on), 2,3mJ (off) | 61ns/310ns | Vcc=400V, Ic=30A, Rg=4,7Ohm, Vge=15V, L=500uH | n/a | -40...+175°C (TJ) | Through Hole | TO-247-3 | - | - | - |