Fabricant
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | - | - | 2V | 300mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | - |
Fabricant
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | - | - | 2V | 175mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | - |
Fabricant
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | - | - | 2V | 175mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | - |
Fabricant
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Combustible gases | 0...5% CH4 | - | ΔR | - | - | 2V | 175mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | - |
Fabricant
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Combustible gases | - | - | ΔR | - | - | 2V | 300mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | - |
Fabricant
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Combustible gases | - | - | ΔR | - | - | 2V | 300mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | - |
Fabricant
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Combustible gases | - | - | ΔR | - | - | 2V | 300mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | - |
Fabricant
SGX SENSORTECH
|
VQ600 | Sensor | Thermal Conductivity | Mixture of known gas and air | x…100% *1 | - | ΔR | 2,5 mV/% CH4, Typ, [3,5V | - | 2...3,5V | 90mA ,Typ. [ 3,5V mA | -20...+60°C | D46x54,8mm | Cable | II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | *1: x depends on gas |
Fabricant
SGX SENSORTECH
|
VQ600 | Sensor | Thermal Conductivity | Mixture of known gas and air | x…100% *1 | - | ΔR | 2,5 mV/% CH4, Typ, [3,5V | - | 2...3,5V | 90mA ,Typ. [ 3,5V mA | -20...+60°C | D46x54,8mm | Cable | II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | *1: x depends on gas |
Fabricant
SGX SENSORTECH
|
VQ600 | Sensor | Thermal Conductivity | Mixture of known gas and air | x…100% *1 | - | ΔR | 2,5 mV/% CH4, Typ, [3,5V | - | 2...3,5V | 90mA, Typ. [ 3,5V mA | -20...+60°C | D46x54,8mm | Cable | II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | *1: x depends on gas |
Fabricant
SGX SENSORTECH
|
VQ600 | Sensor | Thermal Conductivity | Mixture of known gas and air | x…100% *1 | - | ΔR | 1 mV/% CH4, Typ | - | 4,25V | 55mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | *1: x depends on gas |
Fabricant
SGX SENSORTECH
|
VQ600 | Sensor | Thermal Conductivity | Mixture of known gas and air | x…100% *1 | - | ΔR | 1 mV/% CH4, Typ | - | 4,25V | 55mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | *1: x depends on gas |
Fabricant
SGX SENSORTECH
|
VQ600 | Sensor | Thermal Conductivity | Mixture of known gas and air | x…100% *1 | - | ΔR | 1 mV/% CH4, Typ | - | 4,25V | 55mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | *1: x depends on gas |
Fabricant
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Ammonia (NH3) (Hydrogen (H2)) | 0...1,5% NH3 | - | ΔR | - | - | 2V | 100mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | - |
Fabricant
SGX SENSORTECH
|
VQ600 | Sensor | Catalytic | Ammonia (NH3) (Hydrogen (H2)) | 0...1,5% NH3 | - | ΔR | - | - | 2V | 100mA, Typ. mA | -20...+60°C | D46x54,8mm | Cable | ATEX: II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | - |
Fabricant
SGX SENSORTECH
|
- | Sensor | Thermal Conductivity | Mixture of known gas and air | x…100% *1 | - | ΔR | 1 mV/% CH4, Typ | - | 2V | 300mA, Typ. mA | - | D11x8,8mm | Solid legs | II 2G Ex db IIC T5 Gb | MSL 1 | Voltage | *1: x depends on gas |
Fabricant
FIGARO
|
- | Module | NDIR | Carbon dioxide (CO2) | 300...5 000ppm | 1 000ppm, user changable | PWM, I2C/UART | - | ±50ppm + 3% | 5V | 10 mA | 0...+50°C | 32x17x7,4mm | - | Module uses a compact NDIR CO2 sensor | - | CMOS 5V | - |
Fabricant
FIGARO
|
- | Module | NDIR | Carbon dioxide (CO2) | 300...5 000ppm | 1 000ppm, user changable | I2C/UART, PWM | - | ±{50ppm + 3% m.v.) | 5V | 10 mA | 0...+50°C | 32 x 17 x 7,5mm | PCB Pins | - | - | CMOS 5V | - |
Fabricant
SGX SENSORTECH
|
4 series | Sensor | Electrochemical | Ethylene oxide (C2H4O) | 0...100ppm | - | Current | - | - | - | - mA | - | D20x16,6mm | Pins for socket | - | - | - | - |
Fabricant
SGX SENSORTECH
|
4 series | Sensor | Electrochemical | Hydrogen sulfide (H2S) | 0...100ppm | - | Current | 800 ± 200 nA/ppm | - | - | - mA | -20...+50°C | D20x16,6mm | Pins for socket | - | - | - | - |
Fabricant
SGX SENSORTECH
|
4 series | Sensor | Electrochemical | Hydrogen (H2) | 0...1000ppm | - | Current | 20 ± 10 nA/ppm | - | - | - mA | -20...+50°C | D20x16,6mm | Pins for socket | - | - | - | - |
Fabricant
SGX SENSORTECH
|
4 series | Sensor | Electrochemical | Nitrogen dioxide (NO2) | 0...20ppm | - | Current | 600 ± 150 nA/ppm | - | - | - mA | -20...+50°C | D20x16,6mm | Pins for socket | - | - | - | - |
Fabricant
SGX SENSORTECH
|
4 series | Sensor | Electrochemical | Sulfur dioxide (SO2) | 0...20ppm | - | Current | 500 ± 100 nA/ppm | - | - | - mA | -20...+40°C | D20x16,6mm | Pins for socket | - | - | - | - |
Fabricant
SGX SENSORTECH
|
4 series | Sensor | Electrochemical | Chlorine (Cl2) | 0...20ppm | - | Current | 450 ± 200 nA/ppm | - | - | - mA | -20...+50°C | D20x16,6mm | Pins for socket | - | - | - | - |
Fabricant
SGX SENSORTECH
|
4 series | Sensor | Electrochemical | Carbon monoxide (CO) | 0...2000ppm | - | Current | 28 ± 10 nA/ppm | - | - | - mA | -20...+50°C | D20x16,6mm | Pins for socket | - | - | - | - |