French Southern Territories
€ EUR
Prices without VAT

Forget about TVOC measuring. VOC index and SGP40 are coming to the scene

The total volatile organic compounds concentration (TVOC) in ppb cannot be measured by using a single MOS sensor, but the VOC index can. Try it out with the SGP40 sensor in the SEK-SVM40 Sensirion development kit. We have it in our stock.
This is an archive article published 06/09/2021. Some information may no longer be up to date and in line with the current state. Please contact us in case of interest.

Forget about TVOC measuring. VOC index and SGP40 are coming to the scene
TVOC

The total volatile organic compounds (TVOC ) concentration in ppb is the sum of hundreds of different VOCs that are constantly changing in the interior.

TVOC can only be measured by analyzing all individual compounds, for example, by gas chromatography and mass spectrometry (GC-MS).

There is no such method to evaluate TVOC concentration using a single metal oxide semiconductor (MOS) sensor.

VOC Index

Sensirion used a different approach for SGP40. The output of the sensor is a number in the range of 0 to 65 535. That is proportional to the logarithm of the resistance of the sensing layer, which is proportional to the VOC concentration.

Sensirion’s VOC Algorithm running on a standalone microcontroller processes the measured values. The algorithm calculates the average value for the last 24h and assigns it VOC Index = 100, and transforms the measured values into a VOC index in the range 0 to 500. Values between 100 and 500 indicate deterioration; values between 0 and 100 inform about improved air quality.

The algorithm triggers the measurement every second. The current consumption from the 3.3V source is only 2.6 mA, even if the heater is permanently switched on.

The SGP40 features an automatic humidity compensation. All you need is to send the sgp40_measure_raw command with current RH and temperature instead of default 50% and 25°C. Sensirion recommends using humidity compensation, especially in dry environments with absolute humidity less than 5g/m3.

Source codes for the SGP40 driver and VOC Algorithm are available on Sensirion’s GitHub.

VOC Index in “Normal” Environment


Forget about TVOC measuring. VOC index and SGP40 are coming to the scene

VOC Index in “Dirty” Environment


Forget about TVOC measuring. VOC index and SGP40 are coming to the scene

VOC Index of 100 continuously adapts to any environment. Therefore, conditions that were previously interpreted as average (VOC Index = 100) are now considered as air quality improvement.

How to Start?
Forget about TVOC measuring. VOC index and SGP40 are coming to the scene

The easiest way is to connect the SEK-SVM40 evaluation kit directly to a USB port of the PC and run a control center software.

You can also easily connect the kit to an Arduino or Raspberry Pi using the included jumper wires.

The SEK-SVM40 can also serve as a basis for your product. Reference design (PCB + firmware) is available upon request.

Typical Applications

SGP40 is ideal for devices where the sensor is used to trigger and regulate a device. For example, air purifiers, air conditioning, kitchen hoods and thermostats (when linked to a ventilation system). Another typical application is air quality monitoring.

If you need more information about Sensirion products, please contact our sales representative SOS electronic for your region or contact us at sensirion@soselectronic.com; we will be happy to help you.

Videos

SGP40 is Sensirion’s new digital volatile organic compounds (VOC) sensor designed for easy integration into air treatment devices and air quality monitors.

VOC's originate from a number of different possible sources, like building materials, tobacco smoke, people and their activities, and using air fresheners or cleaning agents.
Elevated VOC levels can have various adverse effects on human health.

Do not miss these articles

Do you like our articles? Do not miss any of them! You do not have to worry about anything, we will arrange delivery to you.

Related articles

Main products

SGP40 (SGP40-D-R4) SENSIRION
SENSIRION

Ord.number: 341780

in stock 25 pcs

SGP40 (SGP40-D-R4)

Gas Sensors

Volatile Organic Compounds (VOC) sensor

1 pcs+ 6,27 €

10 pcs+ 5,06 €

100 pcs+ 4,48 €

500 pcs+ 3,85 €

1000 pcs+ 3,58 €

  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare
SHT40-AD1B-R2 SENSIRION
SENSIRION

Ord.number: 343550

in stock 3166 pcs

SHT40-AD1B-R2

Humidity Sensors

Humidity & Temperature Sensor I2C DFN4

2 pcs+ 1,1200 €

100 pcs+ 1,0600 €

500 pcs+ 1,0200 €

1000 pcs+ 0,9870 €

2500 pcs+ 0,9380 €

  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare

Additional products


SEK-SVM40 SENSIRION  
SEK-SVM40

SVM40 module with UART to USB cable and jumper wire set

Development Tools

Ord. No.: 341790
Manufacturer: SENSIRION
No longer available
Do you agree with cookies being stored?
Welcome to the SOS electronic website. Before you enter our online world, we would like to ask you to allow us to store cookies on your browser. Your consent will help us view the site without error, measure its performance, and track additional statistics. Apart from that, we can bring you an offer of our products and services, literally tailor-made. We also provide cookies to third parties. However, you are definitely safe with us.
The proper operation of the website
More stable technical control
Better marketing offer
Necessary Only selected Accept all cookies
Change the settings
Country
Select the country you are located in to receive relevant information and services tailored to your region.
Choose a language
Select your preferred language for displaying website content and communicating with our support.
Currency
Select the currency in which you want to see product prices. This way, we ensure you see current prices tailored to your needs.
Show prices with VAT
Select whether you want to display prices with or without VAT to have a better overview of costs.
Prices without VAT Prices incl. VAT