Notice

You are currently browsing the website for customers from French Polynesia. We recommend switching to the United States version of the site, optimized for your region.
French Polynesia
€ EUR
Prices without VAT

Medical Power Entry Modules with Filter by Schurter

Power entry modules (PEM) with a filter must comply with the basic standard for medical electrical equipment, IEC/UL 60601-1. Let's see how Schurter PEMs meet these requirements. (reading for 5 minutes)

obr2931_pb1c75d87da78.jpg
IEC/UL 60601-1 requirements and PEM solutions with filter by Schurter

Miroslav Piskor, a Product Specialist at SOS electronic, has prepared a summary of the basic requirements of the IEC/UL 60601-1 standard and solutions from Schurter. Thanks to these solutions, electrical devices containing their PEM with a filter meet the demanding requirements in healthcare and home care. 

Power cable

Requirement

Protection of any power connection against unintentional removal of the plug from the equipment’s power socket.

Schurter Solution

  • Cord retaining kits 4700.00XX
  • Screw brackets for universal use 0888.00XX
  • Power cord and PEM with V-Lock. Power socket is equipped with a notch that interlocks with a special latch on the connector on the power cord.

Medical Power Entry Modules with Filter by Schurter

Medical Power Entry Modules with Filter by Schurter

Medical Power Entry Modules with Filter by Schurter

Water Protection

Requirement

IP21 is required for all medical home care equipment (IEC 60601-1-11). Other medical applications may require even higher protection.

Schurter solution

Power entry modules with protection against ingress of water:

  • 5707: IP65 between PEM and device box and IP54 for connected power cord with V-Lock
  • DG11, DG12: IP65 between PEM and device box and IP54 for connected power cord with V-Lock

Medical Power Entry Modules with Filter by Schurter

Fuse Holders

Requirement

Energized supply leads (L) have to be protected by a fuse to minimize the risk that if a failure occurs, the mains circuit breaker might be tripped and disconnecting other, maybe life-critical devices. In some countries the mains plug is not polarized => the power conductor could be on a neutral line! (e.g. CEE plugs in Europe)

Schurter Solution

PEM with a two-pole fuse holder is recommended for all medical electrical equipment.

Requirement

Fuse holders can only be opened with the help of a tool (IEC 60601-1: 5.9.2.1, 8.11.5.).

Schurter Solution

PEM with the “Extra-Safe” fuse drawers and PEM with screw-in fuse drawers (5707 series).

Mains Switches

Requirement

Equipment should be completely disconnected from the power network after being turned off (IEC 60601-1: 8.11.1.).

Schurter Solution

PEM with a two-pole switch that disconnects the power feed on two poles.

Filter – Leakage Currents through PE (filter chassis)

Capacitors wired between the L, N, and PE are Y-capacitors. They produce a leakage current to PE. (current value depends on capacitance, the power-line voltage and frequency).

Medical Power Entry Modules with Filter by Schurter

Requirement

Leakage current for medical electrical equipment must not exceed:

  • 100 µA for devices without direct operator contact, Means Of Operator Protection (MOOP)
  • 10 µA for devices with direct patient contact, Means Of Patient Protection (MOPP)

(IEC 60601-1: 8.7.3.)

Schurter Solution

Power-line filters for medical electric equipment either have no (MOPP -> Schurter M5) or very small (MOOP -> Schurter M80) Y capacitors.

Filter – Safety Capacitors

Capacitors in power-line filters that are wired directly between the L and N conductors are X-class capacitors. Capacitors between L, N, and PE are Y-class capacitors.

Requirement

Y capacitors in medical equipment:

  • Class Y2 for equipment without direct patient contact (MOOP)
  • Class Y1 for equipment with direct patient contact (MOPP)

(IEC 60601-1: 8.5.1.)

Schurter Solution

Schurter M5 PEMs with filter do not contain class Y capacitors. M80 PEMs with filter meet the requirements of IEC 60601-1: 8.5.1.

Filter – Energy Stored in Capacitors

If you unplug the power cord from the outlet, the voltage from the capacitors is present on the power pins until the capacitors are discharged.

Requirement

1 second after unplugging the power cord, the voltage on the pins that can be touched by the operator must be a maximum of 60V (IEC 60601-1: 8.4.3.).

Schurter Solution

PEM with bleeder resistor between the phase and neutral conductors.

Filters – Attenuation

Filters with small Y capacitors (MOOP) or without Y capacitors (MOPP) have low high-frequency attenuation for asymmetric mode (L, N - PE). The situation can be improved a little bit by a filter with ground choke.

Attenuation of standard (1), M80 (2) and M5 (3) 1A filters and 1A M5 filter with ground choke (4).

obr2931_p77ed9cea7eca.jpg

Home Care Medical Equipment

Requirement

IEC 60601-1-11 requires:

  • Protection Class II (Double Insulation)
  • Test voltage 4 000 V between L/N and the filter case
  • Minimum protection against water IP21

Schurter Solution

PEM with:

  • C8 or C18 inlet connectors (without PE)
  • Reinforced insulation inside of the filter
  • 8 mm surface and air distances between live parts and the filter housing
  • PEM will withstand a test voltage greater than 4000 VDC between L/N and the filter housing
  • Topology without Y capacitors

Discover more interesting solutions for electrical devices intended for healthcare and home care in our product range in the special 'medical' product category and in our articles

What value does this article hold for you?

Your feedback helps us create truly useful content for our readers. Appreciate the above information with an imaginary contribution for this article.

Great, thank you for your participation! Your opinion is very important to us.

If you have any questions or comments, please don't hesitate to contact us. Thanks again for your time and trust.


Are you interested in more information about Schurter products or technical advice when selecting a product? Or do you have another question or request? Feel free to contact us; we are happy to assist you.

* Data marked with an asterisk (*) are required.
Do not miss these articles

Do you like our articles? Do not miss any of them! You do not have to worry about anything, we will arrange delivery to you.

Related articles

Main products


5120.1306.0 SCHURTER  
5120.1306.0

Power Entry Module C14 Panel 10A, Filter, M5

Power Entry Modules

Ord. No.: 249556
Manufacturer: SCHURTER
in stock 20 pcs
1 pcs+
2 pcs+
10 pcs+
50 pcs+
8,46 €
7,87 €
7,21 €
6,54 €
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare

5707.0603.313.21 SCHURTER  
5707.0603.313.21

Power Entry Module C14 Panel 6A, Filter, Fuse Holder, M5

Power Entry Modules

Ord. No.: 250226
Manufacturer: SCHURTER
in stock 20 pcs
1 pcs+
2 pcs+
14 pcs+
26,20 €
25,00 €
22,30 €
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare

5707.0603.413 SCHURTER  
5707.0603.413

Power Entry Module C18 Panel 6A, Filter, Fuse Holder, M5

Power Entry Modules

Ord. No.: 250228
Manufacturer: SCHURTER
in stock 20 pcs
1 pcs+
2 pcs+
14 pcs+
26,00 €
24,70 €
22,10 €
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare

4301.8058 SCHURTER  
4301.8058

Power Entry Module C14 Panel 6A, Filter, M5

Power Entry Modules

Ord. No.: 243335
Manufacturer: SCHURTER
in stock 80 pcs
1 pcs+
2 pcs+
12 pcs+
30,00 €
29,20 €
26,30 €
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare

KMF1.1193.11 SCHURTER  
KMF1.1193.11

Power Entry Module C14 Panel 10A, Filter, Switch, Fuse Holder, M5

Power Entry Modules

Ord. No.: 253596
Manufacturer: SCHURTER
in stock 39 pcs
1 pcs+
2 pcs+
14 pcs+
26,50 €
25,20 €
22,60 €
  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare
Do you agree with cookies being stored?
Welcome to the SOS electronic website. Before you enter our online world, we would like to ask you to allow us to store cookies on your browser. Your consent will help us view the site without error, measure its performance, and track additional statistics. Apart from that, we can bring you an offer of our products and services, literally tailor-made. We also provide cookies to third parties. However, you are definitely safe with us.
The proper operation of the website
More stable technical control
Better marketing offer
Necessary Only selected Accept all cookies
Change the settings
Country
Select the country you are located in to receive relevant information and services tailored to your region.
Choose a language
Select your preferred language for displaying website content and communicating with our support.
Currency
Select the currency in which you want to see product prices. This way, we ensure you see current prices tailored to your needs.
Show prices with VAT
Select whether you want to display prices with or without VAT to have a better overview of costs.
Prices without VAT Prices incl. VAT