Notice
You are currently browsing the website for customers from Holy See (Vatican City State). We recommend switching to the United States version of the site, optimized for your region.
Manufacturer
SENSIRION
|
LS32 | Liquid Flow Meter | 40ml/min | 5% or 0,25% FS *1 | Water | 12bar | 1/4-28 flat bottom 1/8ö OD tubing | I2C | +5...+50°C | 5V | *1 Whichever error is larger |
Manufacturer
SENSIRION
|
SCC1 | Liquid Flow Meter Accessory | - | n/a | - | - | - | I2C/0...10V | - | 12...36V | - |
Manufacturer
SENSIRION
|
SCC1 | Liquid Flow Meter Accessory | - | n/a | - | - | - | I2C/0...10V | - | 12...36V | n/a |
Manufacturer
SENSIRION
|
SCC1 | Liquid Flow Meter Accessory | - | n/a | - | - | - | I2C/RS485 | - | 12...36V | n/a |
Manufacturer
SENSIRION
|
SCC1 | Liquid Flow Meter Accessory | - | n/a | - | - | - | I2C/RS485 | - | 12...36V | n/a |
Manufacturer
SENSIRION
|
SFC5400 | Mass Flow Controller for Gases | 50, 100, 200, 500 sccm, 1, 2, 5, 10, 20, 50, 100 slm | - | - | - | Downmount, Swagelok, VCR, VCO, W-Seal | RS485, DeviceNet, IO-Link (optional), analog voltage / current | 0...+50°C | 14...26V | - |
Manufacturer
SENSIRION
|
SFM3xxx | Mass Flow Meter for Gases | ±200slm | 1,5% or 0,05slm *1, Typ. | Air, N2, O2 | 0,7...1,3bar Absolute | 22mm cone/22mm cone, ISO5356 | I2C | -20...+80°C | 5V | *1 Whichever error is larger |
Manufacturer
SENSIRION
|
SFM3xxx | Mass Flow Meter for Gases | ±200slm | 1,5% or 0,05slm *1, Typ. | Air, N2, O2 | 0,7...1,3bar Absolute | 22mm cone/22mm cone, ISO5356 | I2C | -20...+80°C | 5V | *1 Whichever error is larger |
Manufacturer
SENSIRION
|
SFM3xxx | Mass Flow Meter for Gases | -150...300slm | 2,5...3% or 0,05slm *1, Typ. | O2, Air and mixtures of Air/O2 | 0,7...1,3bar Absolute | 22mm cone/22mm cone, ISO5356 | I2C | -20...+85°C | 2,7...5,5V | *1 Whichever error is larger |
Manufacturer
SENSIRION
|
SFM3xxx | Mass Flow Meter for Gases | -30...300slm | 2...2,5% or 0,05slm | O2, Air and mixtures of Air/O2 | 0,7...1,3bar Absolute | 22mm cone/22mm cone, ISO5356 | I2C | -20...+85°C | 2,7...5,5V | *1 Whichever error is larger |
Manufacturer
SENSIRION
|
SFM3xxx | Mass Flow Meter for Gases | -30...300slm | 2% or 0,05slm *1, Typ. | O2, Air and mixtures of Air/O2 | 0,7...1,3bar Absolute | 22mm cone/22mm cone, ISO5356 | I2C | -20...+85°C | 2,7...5,5V | *1 Whichever error is larger |
Manufacturer
SENSIRION
|
SFM3xxx | Mass Flow Meter for Gases | -30...300slm | 2% or 0,1slm (Air), 2...7% or 0,1% FS (HeOx) *1, Typ. | O2, Air, mixtures of Air/O2, HeOx, mixtures O2/HeOx | 0,7...1,3bar Absolute | 22mm cone/22mm cone, ISO5356 | I2C | -20...+85°C | 2,7...5,5V | *1 Whichever error is larger |
Manufacturer
SENSIRION
|
SFM | Mass Flow Meter for Gases | -24...240slm | 2,5...4,5% ±0,02slm, Typ. | Air | 0,6...1,07bar Absolute | 19mm/19mm | Analog 0,095...2,45V | +5...+60°C | 5V | - |
Manufacturer
SENSIRION
|
SFM3100 | Mass Flow Meter for Gases | -10...240slm | 2...5% ±0,02slm, Typ. | Air, O2 and mixtures of Air/O2 | 0,7...1,3bar Absolute | 19mm/19mm | I2C | +5...+60°C | 2,7...5,5V | - |
Manufacturer
SENSIRION
|
SFM3xxx | Mass Flow Meter for Gases | -100...250slm | 2...7% ±0,05slm, Typ. | Air | 0,6...1,07bar Absolute | 22mm cone/22mm socket, ISO5356 | I2C | +10...+50°C | 5V | - |
Manufacturer
SENSIRION
|
SFM4100 | Mass Flow Meter for Gases | 20slm | 3% or 0,15% FS *1, (0...50-C) | Air | 6bar Gauge | Downmount | I2C | -20...+80°C | 3,5~9V | *1 Whichever error is larger |
Manufacturer
SENSIRION
|
SFM4100 | Mass Flow Controller for Gases | 20slm | 3% or 0,15% FS *1, (0...50-C) | Air, N2 | 6bar Gauge | Legris Carstick 6mm | I2C | -20...+80°C | 3,5 - 9V | *1 Whichever error is larger |
Manufacturer
SENSIRION
|
SFM4100 | Mass Flow Meter for Gases | 20slm | 3% or 0,15% FS *1, (0...50-C) | Ar | 6bar Gauge | Downmount | I2C | -20...+80°C | 3,5 - 9V | *1 Whichever error is larger |
Manufacturer
SENSIRION
|
SFM4100 | Mass Flow Meter for Gases | 20slm | 3% or 0,15% FS *1, (0...50-C) | Ar | 6bar Gauge | Legris Carstick 6mm | I2C | -20...+80°C | 3,5 - 9V | *1 Whichever error is larger |
Manufacturer
SENSIRION
|
SFM4100 | Mass Flow Meter for Gases | 20slm | 3% or 0,15% FS *1, (0...50-C) | CO2 | 6bar Gauge | Downmount | I2C | -20...+80°C | 3,5 - 9V | *1 Whichever error is larger |
Manufacturer
SENSIRION
|
SFM4100 | Mass Flow Meter for Gases | 20slm | 3% or 0,15% FS *1, (0...50-C) | CO2 | 6bar Gauge | Legris Carstick 6mm | I2C | -20...+80°C | 3,5 - 9V | *1 Whichever error is larger |
Manufacturer
SENSIRION
|
SFM4100 | Mass Flow Meter for Gases | 20slm | 3% or 0,15% FS *1, (0...50-C) | N2O | 6bar Gauge | Downmount | I2C | -20...+80°C | 3,5 - 9V | *1 Whichever error is larger |
Manufacturer
SENSIRION
|
SFM4100 | Mass Flow Meter for Gases | 20slm | 3% or 0,15% FS *1, (0...50-C) | N2O | 6bar Gauge | Legris Carstick 6mm | I2C | -20...+80°C | 3,5 - 9V | *1 Whichever error is larger |
Manufacturer
SENSIRION
|
SFM4100 | Mass Flow Meter for Gases | 20slm | 3% or 0,15% FS *1, (0...50-C) | O2 | 6bar Gauge | Downmount | I2C | -20...+80°C | 3,5 - 9V | *1 Whichever error is larger |