Austria
€ EUR
Prices without VAT

SCD30 is More Than Just the NDIR CO2 Sensor

Sensirion SCD30 is a calibrated module with NDIR CO2, humidity and temperature sensors. Measuring of CO2 concentration and automatic ventilation on demand guarantees healthy workplace and even saves the energy.
This is an archive article published 03/29/2018. Some information may no longer be up to date and in line with the current state. Please contact us in case of interest.

Why Measure COconcentration?

Health Aspect
American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) recommend maintaining indoor CO2 concentrations at—or below—1,000 ppm in schools and 800 ppm in offices.
At 1000 to 2000ppm of CO2, people complain about drowsiness and poor air. CO2 concentration between 2 000 to 5 000ppm can cause headaches, sleepiness, poor concentration, loss of attention, increased heart rate and slight nausea. 5 000ppm is the daily exposure limit (8hours). 

Energy Consumption
Most heating, ventilation and air conditioning systems (HVAC) re-circulate a significant portion of the indoor air. Air exhaled by humans contains in average 35,000 to 50,000 ppm of CO2 (100 times higher than outdoor air). Without adequate ventilation, the CO2 concentration increases. However, ventilation requires subsequent heating or cooling of the air, which increases energy consumption.

The solution is simplemeasure the concentration of CO2 and ventilate in a way that the CO2 concentration does not exceed the recommended value.

NDIR Sensor Module Principle

NDIR (Non-Dispersive Infra-Red) sensor uses the fact that CO2 molecules absorb infrared radiation of certain wavelengths. The higher the CO2 concentration, the more radiation CO2 absorbs. The wavelength of 4.3μm has the maximum absorption for CO2 and minimal absorption for other gases in the air.

SCD30 is More Than Just the NDIR CO2 Sensor

An infrared radiation source (light bulb) is placed on one side of the tube. On the opposite side, two sensors with optical filters are placed. The first sensor (CO2) has a band-pass filter for wavelength 4.3µm; it measures the intensity of radiation Id. The second sensor (reference) has a band-pass filter for wavelength, which is minimally absorbed by gases in the air (typically 4µm); it measures the intensity of radiation I0.

SCD30 is More Than Just the NDIR CO2 Sensor

The measured intensity of radiation at these wavelengths is then associated with CO2 concentration via the Beer-Lambert Law that is given with the following equation:

Id/I0=e^KCL

where Id is the intensity of radiation at 4.3μm, I0 is the intensity of the reference radiation, K is the absorption coefficient for CO2, C is the COconcentration, and L is the path length between the radiation source and the light detectors.

The reference sensor compensates for the effect of the radiation intensity variation. When intensity changes, both Id and I0 change identically, so Id / I0 remains unchanged.

If you are interested in any Sensirion products, or you need more information, we will be pleased to help at sensirion@soselectronic.com

Features:
  • Calibrated, linearized and temperature compensated module
  • Dual sensor detection guarantees superior long term stability
  • Integrated RH and temperature sensor
  • CO2 measuring range 400...10 000ppm
  • Accuracy ± (30ppm + 3%)
  • I2C and UART interface
Do not miss these articles

Do you like our articles? Do not miss any of them! You do not have to worry about anything, we will arrange delivery to you.

Related articles

Main products

SCD30 SENSIRION
SENSIRION

Ord.number: 290529

in stock 502 pcs

SCD30

Gas Sensors

Calibrated NDIR CO2, Temperature and RH Sensor Module

1 pcs+ 36,60 €

10 pcs+ 35,20 €

40 pcs+ 35,00 €

120 pcs+ 34,70 €

200 pcs+ 34,50 €

  • ADD TO CART
  • Get Quote
  • Add to favorites
  • Add to watchdog
  • Add item to compare
SEK-SCD30 SENSIRION
SENSIRION

Ord.number: 290550

SEK-SCD30

Development Tools

Evaluation Kit for SCD30

No longer available

Get Quote
Do you agree with cookies being stored?
Welcome to the SOS electronic website. Before you enter our online world, we would like to ask you to allow us to store cookies on your browser. Your consent will help us view the site without error, measure its performance, and track additional statistics. Apart from that, we can bring you an offer of our products and services, literally tailor-made. We also provide cookies to third parties. However, you are definitely safe with us.
The proper operation of the website
More stable technical control
Better marketing offer
Necessary Only selected Accept all cookies
Change the settings
Country
Select the country you are located in to receive relevant information and services tailored to your region.
Choose a language
Select your preferred language for displaying website content and communicating with our support.
Currency
Select the currency in which you want to see product prices. This way, we ensure you see current prices tailored to your needs.
Show prices with VAT
Select whether you want to display prices with or without VAT to have a better overview of costs.
Prices without VAT Prices incl. VAT